MSCS - Multiple System Console Solution
Multiple i5 or iSeries AS400
System Consoles over TCP/IP

Full System Console Control for Multiple i5s, iSeries AS/400s or 
a Combination of AS/400®s and LPARs
Over a TCP/IP LAN, WAN or Virtual Private Network (VPN)

Overview

With the TwiNet SNA Gateway you can eliminate the problems of administering the System Console function in a multiple AS/400 environment.  The Multiple System Console Solution (MSCS) configuration will make System Console administration of multiple AS/400s as simple as opening a Window on a LAN attached PC.

The System Console is typically a "dumb" twinax Display Station attached to Port 0 / Address 0 of your AS/400 or LPAR.  The System Console is the only terminal that can:

Click on image above for more screenshots.

bulletPerform certain System Maintenance and Configuration Procedures (Restricted State)
bulletExecute certain type of System Backups (SAVSYS)
bulletRespond to certain types of "System Console Only" messages

In the multiple system environment, this requires one terminal per AS/400.  It also requires that an operator be on site to respond to the message, or perform the particular procedure that can only be executed from the System Console.   When the operator is not on site, it usually requires a phone call or a page to a standby operations person who would need to either travel to the office or diagnose the problem over the phone.

TwiNet MSCS will allow these AS/400 or LPAR "System Console Functions" to be handled from anywhere on your LAN, WAN or VPN.   This also includes dial-in to a network attached Remote Access Server (RAS) such as a Shiva LanRover or a BOSaNOVA LanLynk.  This eliminates the necessity of the AS/400 operator to be at the normal location for the System Console - the computer room.

Featured Highlights

bullet

Manage up to 32 separate AS/400s and/or LPARS from a single TCP/IP PC anywhere on your LAN / WAN / VPN

bulletSupports up to seven twinax Display or Printer sessions (Addresses 0 through 6) on your LAN PCs with the included TwiNet Gold Client Software for each TwiNet Gateway installed
bulletBuilt-in Web Server for easy installation, configuration and monitoring
bulletBundle with TwiNet-Suite - a collection of useful 32-bit software applications and module
bulletManage all TwiNet's on your local LAN with the included Network Manager administrative software

Click here for More Information on the TwiNet Multiple System Console Solution

Multiple System Console Solution (MSCS) Diagram

Diagram:  Multipe TwiNet SNA Gateways connecting to multiple iSereis and LPARs to provide full System Console control over a TCP/IP connection from anywhere on the corporate LAN, WAN or VPN.

Click here for More Information on the TwiNet Multiple System Console Solution

Applications for MSCS with TwiNet

bulletControl Multiple AS/400s  or LPARs from a single "System Console"
bulletControl an AS/36 and AS/400 from the same System Console - Allows upgrading from one system to a new system to be more convenient.  You can also configure additional sessions from each system, up to seven (7) from each TwiNet SNA Gateway.
bulletAllow a local network PC to be System Console for an AS/400 at a remote location - Improves system operation capabilities at other locations without the need for a system operator.
bulletAllow System Consoles to be anywhere on your LAN/WAN/VPN

Some Features of MSCS with TwiNet

bulletFlexible Twinax connection means increased productivity. The TwiNet solution uses a Twinax connection to the host IBM midrange system which means that it can support the IBM AS/400, System/36, Advanced Series/36 and Twinax Remote Controllers. Since TwiNet provides a single point of contact to the midrange host, there is less configuration and operating overhead, providing better overall host performance.
bulletSimple, intuitive installation and configuration. On the PC side, a single protocol can be used for both LAN and host PCs, and since TwiNet is a native Twinax gateway, it does not require the overhead and configuration complexities of an APPC router.  And the TwiNet Gold Client software installs quickly and easily, using industry-standard LAN interfaces.

TwiNet SNA Gateway

TwiNet Installation example The picture on the left shows a standard TwiNet installation. The IBM Host can be any S/3X, AS/400 or Remote Control Unit with a Twinax attachment installed. TwiNet can be installed either close to the Host or close to the Clients, using the existing Twinax or UTP cabling very good for long distance connection (up to 5000 feet).

TwiNet support any Windows'95/98/2000 or NT Client. More technical information is available at the following page: TwiNet Data Sheet.

Technical Specifications

Specification 

Description

Operating System

PC Side: 

Windows 95, 98, 2000, NT, ME, XP

Host Side side:

AS/400 - iSeries: V3R2 to V5R2

Advanced Series/36:  All

System/36:  All

Connectors

 

1 RJ 45 10BaseT, 100BaseT (auto-sensing)
Twinax Y-Cable with Cable-thru capability for connection to Twinax Host Port

LEDs

Power, Link, 10/100, Check, Alert, Packet and Collision.

Main Power 

100-240V AC 50-60Hz

Dimensions

Height

1.85 in. /  

  47 mm

Width

8.66 in. / 

  220 mm

Depth

5.7 in. / 

  144 mm

Weight

1.65 Lb. /  0.75 Kg.

Temperature and
Relative Humidity

50°F to 104°F / 10°C to 40°C
8% to 85%

Certifications

CE –EN 55022 – EN 50082-1 – FCC Class A

Warranty

One Year 

Click here for More Information on the TwiNet Multiple System Console Solution


Ordering Information

ITEM NO. PRODUCT OPERATING SYSTEMS

CM-TWINET

TwiNet SNA Gateway
One required for each AS/400 or LPAR 

Windows 95, 98, 2000, NT, ME, XP

Download the TwiNet Data Sheet

MSCS TwiNet Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me
My Need is: Immediate 30 Day 60 Day 90 Day

I'm Interested In Information on:

Type of AS400/Mainframe/Host System:

Name
Title
Company
Address 1
Address 2
City, State/Province ,  
ZIP/Postal Code
Country
E-mail
Phone Ext.
FAX

How did you hear
about  this  product ?

For more information on TwiNet, contact us at 800-597-2525
or e-mail us at info@twindata.com

Click on the links below to go to:
MSCS - Multiple System Console Solution
TwiNetTC - System Console Control of Multiple AS/400s or LPARs

 

[Home] [Products] [Manufacturers] [Weekly Special] [Services] [Search] [Shopping] [News]
[Quick Links] [Feedback] [Site Map] [Company & Contact Information] [Warranty & Technical Support]

PLEASE CLICK HERE to send us questions or comments about this web site.
Copyright © 2009 Twin Data Corporation - Phone (800)597-2525 - International (908)688-8100 - FAX (908)688-8160