			you are not transferred to that page within a few seconds. OverviewThe I-O 
                  Xip+ Twinax Controller connects IBM and IBM compatible 
                  Twinax display stations and printers to any 
		model AS400, iSeries 
		or System 
		i host 
                  via TCP/IP over an Ethernet LAN, WAN or the 
		Internet. The Xip+ is ideal for those who are 
			moving to a new Power8 or Power7 and those migrating 
		any model iSeries AS/400 to an 
		all Ethernet environment. 
			The 
			various models of the 
			Xip+ support 
	from 1 Twinax Printer  to 42 Twinax 
	Devices/Addresses. Click here to see the various models available.  
	 
 
		
			| 
	Advantages
				
				
				Connect 
				Reliable Twinax Displays and
				Twinax printers to 
				IBM Hosts over any TCP/IP or Ethernet LAN / WAN / VPN
				Eliminates the need for expensive IBM Twinax Work Station 
                    Controllers
				
				IP Replacement for Twinax Remote Controllers - 
				In locations requiring remote access, the I-O 
					Xip+ replaces 
                    expensive remote controllers
				
				Connects over ANY IP Connection - 
				No need for high-priced leased lines or expensive
                    DSU/CSU 
                    modems
				No re-cabling 
					- continue to utilize existing Twinax 
                    or twisted pair cabling
				
				Explicit Device Names - use the same device names you 
					are currently using
				
				Share Printers with Up to 4 Systems or LPARs -
				connect the 
				same Twinax Printer to multiple systems
				
				Nine Different 
				Models Available: 
					
						| 
				LAN-RPC+ | 
				 Support for 1 Twinax Printer  |  
						| 
				Xip+ 7  | 
				 Support for 7 Twinax Devices  |  
						| 
				Xip+ 7D   | 
				 Desktop Version of the Xip+ 7 |  
						| 
				Xip+ 14  | 
				 Support for 14 Twinax Devices |  
						| 
				Xip+ 14D   | 
				 Desktop Version of the Xip+ 14 |  
						| 
				Xip+ 21  | 
				 Support for 21 Twinax Devices |  
						| 
				Xip+ 28  | 
				 Support for 28 Twinax Devices |  
						| 
				Xip+ 35   | 
				 Support for 35 Twinax Devices |  
						| 
				Xip+ 42  | 
				 Support for 42 Twinax Devices |  
				
				
				Click here or scroll down to see images of all Xip+ models:
				
				Connect to Multiple Hosts - Supports 
					connection up to 
					four (4)
				IBM Power9, Power8,  Power7, or any iSeries AS/400 hosts (V3R2 or higher)
				
				Supports 
					Multiple Protocols -  TN5250e, 
				AnyNet and SNA
				
				Easy to install
				
				3-Year Advanced Exchange Warranty 
				(North America) |  
			|  |  
			|  
			 |  Click here for
        more information on the Xip+ Controller 
		Click
      here to download the Xip+ Controller Datasheet
		  Specifications
        
        
        
        
                | ? General- Attaches up to
				42 Twinax
 displays
				and printers
 - Supports up to 4 hosts
 - Allows up to 4 sessions per Twinax
 address
 - Supports TCP/IP (TN5250e, AnyNet)
 and SNA protocols
 
 • Host Systems and Requirements
 - AS/400-iSeries-System 
				i
 - OS400 V3R2 and newer
 - TCP/IP
 - Telnet services
 
 • Display Stations
 - All 5250 Twinax display stations
 - Display model type is matched to
 Telnet models:
 5251-11, 
                    5291-1, 5292-2,
 3180-2, 3179-2, 3196-A1, 3477-FG,
 3477-FC (InfoWindow II and Extended
 Character Attributes not supported)
  • Printers- All 5250 SCS and IPDS Twinax
 printers
 - TN5250e – host configures all SCS
 printers as 3812-1
 - AnyNet – host recognizes the
 printer’s model
					type
 - SNA – host recognizes the printer’s
 model
					type
 
 • Data Streams
 - TN5250e, auto configuring local and
 remote connectivity (SCS)
 - AnyNet, auto configuring local and
 remote connectivity
					(IPDS and SCS)
 - SNA, auto configuring local
 connectivity
 (IPDS 
                    and SCS)
 |  
                   
                  • Network- 10/100 BaseT auto-sensing
 - TCP/IP (TN5250e, AnyNet)
 - DHCP client
 - SNA (APPC)
 - Ethernet (IEEE 802.2, 802.3)
 
 • Ports
 - RJ45 for Ethernet
 - Xip+ 42 - Six Twinax Host 
					Ports
 - Xip+ 
					35 - Five Twinax Host 
					Ports
 - Xip+ 28 
					- Four Twinax Host Ports
 - Xip+ 21 - Three Twinax Host 
					Ports
 - Xip+ 
					14 - Two Twinax Host 
					Ports
 - Xip+ 7   
					- One Twinax Host Port
 - DB25 parallel for diagnostic
 printouts
 
 • Approvals
 - Logic Unit – FCC 15, CE
 - Power Supply ? UL, CE
 
 • Power Supply
 - Input – 12 volt DC - 3 
					amp
 
 • Physical - XIP+
 - 19" Rack 
					Mountable (1.5 U)
 (17"w x 6.5"d x 1.75"h)
  
                  
  
                  • Physical - XIP+D Desktop- 10"w x 
					9.5"d x 2.25h
 
 |  Click here for
        more information on the Xip+ Controller 
		Click
      here to download the Xip+ Controller Datasheet
		  Additional Features
        
        
          
            | 
			FEATURES | 
			BENEFITS |  
                | Investment Protection | When installing an Ethernet LAN 
                  that is attached to an AS/400–iSeries, reliable Twinax 
                  displays and IPDS/SCS printers can operate in the new Ethernet 
                  environment maintaining the usefulness of the equipment |  
                | Eliminates the Need 
                  for Twinax Work Station Controller | A significant saving is realized 
                  by installing an I-O Xip+ Twinax Controller instead of an 
                  expensive IBM Twinax Work Station Controller |  
                | No
                  IBM Remote Controller 
                  Required | When remote access to an AS/400–iSeries 
                  is required, an expensive IBM or IBM compatible remote controller 
                  is replaced by an economical I–O Xip+ Controller |  
                | No Leased Lines or 
                  Expensive Modems | When communicating to a remote 
                  site, there is no need to spend valuable resources on high-priced 
                  leased lines and special modems. |  
                | No Re-cabling | The I-O 
				Xip+ allows Twinax displays 
                  and printers to be connected to existing Twinax or twisted pair 
                  cabling eliminating the expense of re-cabling |  
                | Multiple Protocols | Supports the auto configuring 
                  TN5250e and AnyNet for remote locations or SNA for a local attachment |  
                | Multiple Host | Supports up to 4 hosts |  
                | Multiple Sessions | Up to 4 sessions per physical 
                  device address can be configured – Up to 56 logical sessions supported |  